{"product_id":"camden-cm-rqe70a-pir-request-to-exit-detector","title":"CAMDEN CM-RQE70A: PIR Request-to-Exit Detector","description":"\u003ch2\u003e\u003cstrong\u003eCall: 800-888-8101\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003ca href=\"https:\/\/www.pamdist.com\/pages\/dealer-application\"\u003e\u003cstrong\u003eFill Out Customer Application\u003c\/strong\u003e\u003c\/a\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cbr\u003ePN \/ CAM-CM-RQE70A * | \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0478\/8893\/files\/Camden-CM-RQE70A-Install-Manual.pdf?v=1793130002\" rel=\"noopener\" target=\"_blank\"\u003eDownload data sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cbr\u003eCamden CM-RQE70A PIR Request-to-Exit Detector\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eIntelligent, Touch-Free Exit Detection in a Compact Door-Frame Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCamden CM-RQE70A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a compact passive infrared motion detector designed to provide touch-free request-to-exit activation for access-controlled doors. Mounted above the doorway on the secure side, it detects an approaching occupant and signals the access-control system to release the locking hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith dual Form “C” relay contacts, adjustable detection coverage, multiple operating modes, and convenient push-button programming, the CM-RQE70A provides installers with a flexible solution for commercial access-control and automatic-door applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePassive Infrared Motion Detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Detects movement from the secure side of an access-controlled doorway.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTouch-Free Request-to-Exit Activation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Allows occupants to exit without pressing a button or presenting a credential.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCompact Door-Frame Design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Slim housing is designed for mounting directly above the doorway.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOnboard Wiring Terminal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Simplifies installation and field connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePush-Button Programming\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Allows easy configuration without DIP switches.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFour Factory-Default Modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Provides quick setup for common door-control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFully Customizable Mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Allows operating attributes to be configured for specialized installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSelectable Fail-Safe or Fail-Secure Operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Adapts to different locking and security requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTwo Form “C” Relay Contacts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Provides flexible normally open and normally closed output connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMomentary or Latching Relay Modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Supports a variety of access-control and door-operator configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAdjustable Detection Coverage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Offers mechanical horizontal and vertical adjustment with electronic range and sensitivity control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eUp to 10 × 10-Foot Coverage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Provides a broad adjustable detection area.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAdjustable Time Delay\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Selectable 5-, 15-, 30-, 45-, or 60-second relay timing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSecondary Activation Input\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Supports connection to an additional activation device.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCard or Keypad Input\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Allows integration with compatible access-control credentials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDoor-Position Input\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Supports connection to a normally open door-position switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAdditional REX Input\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Accepts a secondary normally open request-to-exit device.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBuilt-In Adjustable Sounder\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Provides audible notification with selectable on\/off operation and volume control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTamper Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Helps identify unauthorized removal or interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eActivation LED\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Provides clear visual indication during operation and setup.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eUL Security Listed and RoHS Compliant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — Designed to meet recognized security and environmental standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eFlexible Door-Control Integration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe CM-RQE70A can be programmed for momentary or latching operation and includes inputs for a secondary activation device, credential reader, door-position switch, and request-to-exit device. Its two Form “C” relay contacts provide flexible control of electric strikes, magnetic locks, automatic-door operators, and access-control panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIdeal Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess-controlled interior doors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic-lock installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectric-strike systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic-door operators\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOffices and commercial facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRetail and hospitality properties\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSchools and institutional buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHealthcare facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTouch-free exit applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-traffic controlled doorways\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDetection Technology:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Passive infrared\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOperating Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 12\/24V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Current Draw:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelay Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2 × Form “C” (DPDT)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eContact Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3A at 30V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOperating Modes:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4 factory-default modes and 1 fully customizable mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelay Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Momentary or latching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFail Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Selectable fail-safe or fail-secure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Coverage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10 feet wide × 10 feet high\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCoverage Adjustment:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Horizontal and vertical mechanical adjustment with electronic sensitivity and range control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTime Delay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 5, 15, 30, 45, or 60 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSounder:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Adjustable on\/off and volume\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePiezo Buzzer Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 92 dB at 10 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Card\/keypad, door-position switch, request-to-exit, and secondary activation device\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTamper Contact Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50 mA at 12V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 32°F to 120°F (0°C to 50°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOperating Humidity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0–93% RH, non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 7 × 1.75 × 1.75 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0.25 lbs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eColor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e White\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCamden CM-RQE70A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines adjustable PIR detection, flexible relay control, convenient onboard programming, and multiple system inputs in a compact housing—making it a dependable request-to-exit solution for professional access-control installations.\u003c\/span\u003e\u003c\/p\u003e","brand":"Camden","offers":[{"title":"Default Title","offer_id":41858533752890,"sku":"CAM-CM-RQE70A","price":76.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0478\/8893\/files\/Screenshot2026-10-27143904.png?v=1793130052","url":"https:\/\/www.pamdist.com\/products\/camden-cm-rqe70a-pir-request-to-exit-detector","provider":"PAM Distributing","version":"1.0","type":"link"}